University of Hertfordshire

From the same journal

By the same authors

Standard

A prototype personal aerosol sampler based on electrostatic precipitation and electrowetting-on-dielectric actuation of droplets. / Foat, T. G.; Sellors, W. J.; Walker, M. D.; Rachwal, P. A.; Jones, J. W.; Despeyroux, D. D.; Coudron, L.; Munro, I.; McCluskey, D. K.; Tan, C. K L; Tracey, M. C.

In: Journal of Aerosol Science, Vol. 95, 01.05.2016, p. 43-53.

Research output: Contribution to journalArticle

Harvard

APA

Foat, T. G., Sellors, W. J., Walker, M. D., Rachwal, P. A., Jones, J. W., Despeyroux, D. D., ... Tracey, M. C. (2016). A prototype personal aerosol sampler based on electrostatic precipitation and electrowetting-on-dielectric actuation of droplets. Journal of Aerosol Science, 95, 43-53. https://doi.org/10.1016/j.jaerosci.2016.01.007

Vancouver

Author

Foat, T. G. ; Sellors, W. J. ; Walker, M. D. ; Rachwal, P. A. ; Jones, J. W. ; Despeyroux, D. D. ; Coudron, L. ; Munro, I. ; McCluskey, D. K. ; Tan, C. K L ; Tracey, M. C. / A prototype personal aerosol sampler based on electrostatic precipitation and electrowetting-on-dielectric actuation of droplets. In: Journal of Aerosol Science. 2016 ; Vol. 95. pp. 43-53.

Bibtex

@article{a5e4bd1808d84855a4c9f34325e31716,
title = "A prototype personal aerosol sampler based on electrostatic precipitation and electrowetting-on-dielectric actuation of droplets",
abstract = "An electrostatic precipitator (ESP) based personal sampler with a laboratory based electrowetting-on-dielectric (EWOD) concentrator could provide a high concentration rate personal aerosol sampler system. A prototype system has been developed based on the concept of a lightweight personal ESP collecting aerosol particles onto a hydrophobic surface followed by the use of an EWOD actuated droplet system to transfer the deposited sample into a microlitre size water droplet.A personal sampler system could provide military or civilian personnel with a wide area biological monitoring capability supplying information on who has been infected, what they have been infected with, how much material they were exposed to and possibly where and when they were infected. Current commercial-off-the-shelf (COTS) personal sampler solutions can be bulky and use volumes of water to extract the sample that are typically a thousand times greater than the proposed method.Testing of the prototype ESP at a sample flow rate of 5Lmin-1 demonstrated collection efficiencies greater than 80{\%} for sodium fluorescein particles larger than 4μm diameter and of approximately 50{\%} at 1.5μm. The ESP-EWOD system collection efficiency measured for Bacillus atrophaeus (BG) spores with an air sample flow rate of 20L min-1 was 2.7{\%} with a concentration rate of 1.9×105 min-1. This was lower than expected due to the corona ions from the ESP affecting the hydrophobicity of the collection surface and hence the EWOD efficiency. However, even with this low efficiency the concentration rate is more than an order of magnitude higher than the theoretical maximum of the best current COTS personal sampler. For an optimised system, ESP-EWOD system efficiency should be higher than 32{\%} with a comparable increase in concentration rate.",
keywords = "Aerosol collection, Electrostatic precipitator, Electrowetting-on-dielectric, EWOD, Personal sampler",
author = "Foat, {T. G.} and Sellors, {W. J.} and Walker, {M. D.} and Rachwal, {P. A.} and Jones, {J. W.} and Despeyroux, {D. D.} and L. Coudron and I. Munro and McCluskey, {D. K.} and Tan, {C. K L} and Tracey, {M. C.}",
note = "This is an Open Access article, distributed under the terms of the Open Government Licence. http://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/ Crown Copyright {\circledC} 2016. Published by Elsevier Ltd. All rights reserved. The version of record (T. G. Foat, et al, 'A prototype personal aerosol sampler based on electrostatic precipitation and electrowetting-on-dielectric actuation of droplets', Journal of Aerosol Science, Vol. 95, pp. 43-53, May 2016) is available online at doi: https://doi.org/10.1016/j.jaerosci.2016.01.007.",
year = "2016",
month = "5",
day = "1",
doi = "10.1016/j.jaerosci.2016.01.007",
language = "English",
volume = "95",
pages = "43--53",
journal = "Journal of Aerosol Science",
issn = "0021-8502",
publisher = "Elsevier Limited",

}

RIS

TY - JOUR

T1 - A prototype personal aerosol sampler based on electrostatic precipitation and electrowetting-on-dielectric actuation of droplets

AU - Foat, T. G.

AU - Sellors, W. J.

AU - Walker, M. D.

AU - Rachwal, P. A.

AU - Jones, J. W.

AU - Despeyroux, D. D.

AU - Coudron, L.

AU - Munro, I.

AU - McCluskey, D. K.

AU - Tan, C. K L

AU - Tracey, M. C.

N1 - This is an Open Access article, distributed under the terms of the Open Government Licence. http://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/ Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved. The version of record (T. G. Foat, et al, 'A prototype personal aerosol sampler based on electrostatic precipitation and electrowetting-on-dielectric actuation of droplets', Journal of Aerosol Science, Vol. 95, pp. 43-53, May 2016) is available online at doi: https://doi.org/10.1016/j.jaerosci.2016.01.007.

PY - 2016/5/1

Y1 - 2016/5/1

N2 - An electrostatic precipitator (ESP) based personal sampler with a laboratory based electrowetting-on-dielectric (EWOD) concentrator could provide a high concentration rate personal aerosol sampler system. A prototype system has been developed based on the concept of a lightweight personal ESP collecting aerosol particles onto a hydrophobic surface followed by the use of an EWOD actuated droplet system to transfer the deposited sample into a microlitre size water droplet.A personal sampler system could provide military or civilian personnel with a wide area biological monitoring capability supplying information on who has been infected, what they have been infected with, how much material they were exposed to and possibly where and when they were infected. Current commercial-off-the-shelf (COTS) personal sampler solutions can be bulky and use volumes of water to extract the sample that are typically a thousand times greater than the proposed method.Testing of the prototype ESP at a sample flow rate of 5Lmin-1 demonstrated collection efficiencies greater than 80% for sodium fluorescein particles larger than 4μm diameter and of approximately 50% at 1.5μm. The ESP-EWOD system collection efficiency measured for Bacillus atrophaeus (BG) spores with an air sample flow rate of 20L min-1 was 2.7% with a concentration rate of 1.9×105 min-1. This was lower than expected due to the corona ions from the ESP affecting the hydrophobicity of the collection surface and hence the EWOD efficiency. However, even with this low efficiency the concentration rate is more than an order of magnitude higher than the theoretical maximum of the best current COTS personal sampler. For an optimised system, ESP-EWOD system efficiency should be higher than 32% with a comparable increase in concentration rate.

AB - An electrostatic precipitator (ESP) based personal sampler with a laboratory based electrowetting-on-dielectric (EWOD) concentrator could provide a high concentration rate personal aerosol sampler system. A prototype system has been developed based on the concept of a lightweight personal ESP collecting aerosol particles onto a hydrophobic surface followed by the use of an EWOD actuated droplet system to transfer the deposited sample into a microlitre size water droplet.A personal sampler system could provide military or civilian personnel with a wide area biological monitoring capability supplying information on who has been infected, what they have been infected with, how much material they were exposed to and possibly where and when they were infected. Current commercial-off-the-shelf (COTS) personal sampler solutions can be bulky and use volumes of water to extract the sample that are typically a thousand times greater than the proposed method.Testing of the prototype ESP at a sample flow rate of 5Lmin-1 demonstrated collection efficiencies greater than 80% for sodium fluorescein particles larger than 4μm diameter and of approximately 50% at 1.5μm. The ESP-EWOD system collection efficiency measured for Bacillus atrophaeus (BG) spores with an air sample flow rate of 20L min-1 was 2.7% with a concentration rate of 1.9×105 min-1. This was lower than expected due to the corona ions from the ESP affecting the hydrophobicity of the collection surface and hence the EWOD efficiency. However, even with this low efficiency the concentration rate is more than an order of magnitude higher than the theoretical maximum of the best current COTS personal sampler. For an optimised system, ESP-EWOD system efficiency should be higher than 32% with a comparable increase in concentration rate.

KW - Aerosol collection

KW - Electrostatic precipitator

KW - Electrowetting-on-dielectric

KW - EWOD

KW - Personal sampler

UR - http://www.scopus.com/inward/record.url?scp=84957058329&partnerID=8YFLogxK

U2 - 10.1016/j.jaerosci.2016.01.007

DO - 10.1016/j.jaerosci.2016.01.007

M3 - Article

VL - 95

SP - 43

EP - 53

JO - Journal of Aerosol Science

JF - Journal of Aerosol Science

SN - 0021-8502

ER -