TY - JOUR
T1 - A comparison of methods to estimate anaerobic capacity: Accumulated oxygen deficit and W' during constant and all-out work-rate profiles.
AU - Muniz, Daniel
AU - Pedlar, Charles
AU - Godfrey, Richard
AU - Glaister, Mark
N1 - This document is the Pre-Print version of an article first published by Taylor & Francis Group in Journal of Sports Sciences, on December 2016, available online at:http://www.tandfonline.com/doi/full/10.1080/02640414.2016.1267386.
The Accepted Manuscript version is under embargo. Embargo end date: 26 June 2018.
PY - 2017/12/2
Y1 - 2017/12/2
N2 - This study investigated (i) whether the accumulated oxygen deficit (AOD) and curvature constant of the power-duration relationship (W') are different during constant work-rate to exhaustion (CWR) and 3-min all-out (3MT) tests and (ii) the relationship between AOD and W' during CWR and 3MT. Twenty-one male cyclists (age: 40 ± 6 years; maximal oxygen uptake [V̇O2max]: 58 ± 7 ml · kg-1 · min-1) completed preliminary tests to determine the V̇O2-power output relationship and V̇O2max. Subsequently, AOD and W' were determined as the difference between oxygen demand and oxygen uptake and work completed above critical power, respectively, in CWR and 3MT. There were no differences between tests for duration, work, or average power output (P ≥ 0.05). AOD was greater in the CWR test (4.18 ± 0.95 vs. 3.68 ± 0.98 L; P = 0.004), whereas W' was greater in 3MT (9.55 ± 4.00 vs. 11.37 ± 3.84 kJ; P = 0.010). AOD and W' were significantly correlated in both CWR (P < 0.001, r = 0.654) and 3MT (P < 0.001, r = 0.654). In conclusion, despite positive correlations between AOD and W' in CWR and 3MT, between-test differences in the magnitude of AOD and W', suggest that both measures have different underpinning mechanisms.
AB - This study investigated (i) whether the accumulated oxygen deficit (AOD) and curvature constant of the power-duration relationship (W') are different during constant work-rate to exhaustion (CWR) and 3-min all-out (3MT) tests and (ii) the relationship between AOD and W' during CWR and 3MT. Twenty-one male cyclists (age: 40 ± 6 years; maximal oxygen uptake [V̇O2max]: 58 ± 7 ml · kg-1 · min-1) completed preliminary tests to determine the V̇O2-power output relationship and V̇O2max. Subsequently, AOD and W' were determined as the difference between oxygen demand and oxygen uptake and work completed above critical power, respectively, in CWR and 3MT. There were no differences between tests for duration, work, or average power output (P ≥ 0.05). AOD was greater in the CWR test (4.18 ± 0.95 vs. 3.68 ± 0.98 L; P = 0.004), whereas W' was greater in 3MT (9.55 ± 4.00 vs. 11.37 ± 3.84 kJ; P = 0.010). AOD and W' were significantly correlated in both CWR (P < 0.001, r = 0.654) and 3MT (P < 0.001, r = 0.654). In conclusion, despite positive correlations between AOD and W' in CWR and 3MT, between-test differences in the magnitude of AOD and W', suggest that both measures have different underpinning mechanisms.
KW - AOD
KW - high-intensity
KW - anaerobic work capacity
KW - anaerobic
U2 - 10.1080/02640414.2016.1267386
DO - 10.1080/02640414.2016.1267386
M3 - Article
SN - 0264-0414
VL - 35
SP - 2357
EP - 2364
JO - Journal of Sports Sciences
JF - Journal of Sports Sciences
IS - 23
ER -