In this study, the optimal PCM position for energy-saving potential in multi-layered PCM wall buildings with windows has been investigated, focusing on moderating indoor temperatures and reducing heating and cooling loads. An experimental setup was constructed to measure the thermal behaviour of the PCM wall with a double-glazed window. The results indicated that the optimal PCM positions were in an arrange of 341mm and 356mm measured from the external surface of the wall through which the energy consumption for heating and cooling could be reduced by approximately 34-37% and yielded both a moderate PMV maximum value of 0.21 and a PPD value of 6.0%. As the PCM distance was increased from the outer wall layer to the inner wall layer, the heat transfer rate across the wall followed an exponentially decaying function combined with a sinusoidal component, influenced by a phase shift, amplitude modification, and a constant offset. This reduction in heat transfer was achieved through the PCM’s capacity to absorb and release latent heat, thereby stabilising indoor temperatures and reducing dependency on HVAC systems. These findings underscore the potential of PCM layers to contribute to the design of more energy-efficient and sustainable building and wall structures.
Original language | English |
---|---|
Article number | 104381 |
Pages (from-to) | 1-11 |
Number of pages | 11 |
Journal | Sustainable Energy Technologies and Assessments |
Volume | 80 |
Early online date | 10 Jun 2025 |
DOIs | |
Publication status | E-pub ahead of print - 10 Jun 2025 |
Keywords
- Phase change materials,
- energy efficiency
- thermal performance
- multi-layered wall
- buildings
- Phase change materials
- Buildings
- Energy efficiency
- Multi-layered wall
- Thermal performance