Abstract
Power converters play an important role as an enabling technology in the electric power industry, especially in Wind
Energy Systems (WESs). Where they ensure to regulate the exchanging powers between the system and the grid. Therefore;
any fault occurs in any parts of these converters for a limited time without eliminating, it may degrade the system stability and
performance.
This paper presents a new artificial intelligence-based detection method of open switch faults in power converters connecting doubly-fed induction (DFIG) generator wind turbine systems to the grid. The detection method combines a simple Fault Tolerant Control (FTC) strategy with fuzzy logic and uses rotor current average values to detect the faulty switch in a very short period of time. In addition, following a power switch failure, the FTC strategy activates the redundant leg and restores the operation of the converter. In order to improve the performance of the closed-loop system during transients and faulty
conditions, current control is based on a PI (proportional-integral) controller optimized using genetic algorithms. The simulation model was developed in Matlab/Simulink environment and the simulation results demonstrate the effectiveness of the proposed FTC method and closed-loop current control scheme
Energy Systems (WESs). Where they ensure to regulate the exchanging powers between the system and the grid. Therefore;
any fault occurs in any parts of these converters for a limited time without eliminating, it may degrade the system stability and
performance.
This paper presents a new artificial intelligence-based detection method of open switch faults in power converters connecting doubly-fed induction (DFIG) generator wind turbine systems to the grid. The detection method combines a simple Fault Tolerant Control (FTC) strategy with fuzzy logic and uses rotor current average values to detect the faulty switch in a very short period of time. In addition, following a power switch failure, the FTC strategy activates the redundant leg and restores the operation of the converter. In order to improve the performance of the closed-loop system during transients and faulty
conditions, current control is based on a PI (proportional-integral) controller optimized using genetic algorithms. The simulation model was developed in Matlab/Simulink environment and the simulation results demonstrate the effectiveness of the proposed FTC method and closed-loop current control scheme
Original language | English |
---|---|
Pages (from-to) | 652-659 |
Number of pages | 8 |
Journal | International Journal of Renewable Energy Research (IJRER) |
Volume | 7 |
Issue number | 2 |
Publication status | Published - 30 Jun 2017 |
Keywords
- doubly fed induction generator
- wind turbine
- open switch fault
- fuzzy logic
- maximum power point tracking
- grid side converter
- genetic algorithm
- fault tolerant control