Abstract
Condensate retention has been found an important parameter for heat transfer on horizontal enhanced condensing tubes. In this research, five pin-fin (varying in circumferential pin spacing) and three integral-fin horizontal tubes are investigated for condensate retention angle (which is measured from the top of tooth to the fully flooded flank) using water-ethanol mixture. An attempt was made to find the optimum concentration of ethanol in water for maximum retention angle. Concentration of ethanol was varied in between 0.5% to 1.5% by weight. Data revealed the importance of integral-fin tube over pin-fin tube as significant increase in retention angle was observed for integral-fin tube (having same longitudinal spacing, tooth thickness, tooth height, inner and outer diameter) while retention angle for pin-fin tubes remain unchanged. Optimum ethanol concentration was observed to be 0.75%.
Original language | English |
---|---|
Article number | 236A |
Pages (from-to) | 3493-3500 |
Number of pages | 8 |
Journal | Thermal Science |
Volume | 23 |
DOIs | |
Publication status | Published - 2019 |
Keywords
- Binary mixture
- Condensate retention
- Dropwise condensation
- Pin-fin and integral-fin tubes
- Water-ethanol mixture