TY - JOUR
T1 - Experimental study on the optimization of thermal environment and airflow organization in a ventilated underground refuge chamber using deflectors
AU - Jin, Hang
AU - Zhang, Zujing
AU - Mao, Ruiyong
AU - Zhou, Jiri
AU - Wu, Hongwei
AU - Liang, Xing
N1 - © 2025 The Author(s). Published by Elsevier Ltd. This is an open access article under the Creative Commons Attribution Non-Commercial No-Derivatives CC BY-NC-ND licence, https://creativecommons.org/licenses/by-nc-nd/4.0/
PY - 2025/3/11
Y1 - 2025/3/11
N2 - Acceptable temperature is crucial for underground refuge chamber (URC) to ensure the safety and comfort of occupants. A novel temperature control scheme combining mechanical ventilation with deflectors was proposed for URCs. In this study, the effects of ventilation rate (VR), deflector height and deflector angle on ambient temperature control performance and airflow organization of URC were investigated through orthogonal experiments. Results show that: (Ⅰ) The ambient temperature gradient of URC decreases with the increase of VR and deflector height. (Ⅱ) With VR of 350 m3/h, deflector height of 1.40 m, and deflector angle of 0°, compared to the situation without deflectors, the temperature unevenness coefficient can be effectively reduced, the head-to-foot temperature difference can meet the design standard requirements, the waste heat emissions efficiency is increased by 46.1 %, and an average decrease in ambient temperature of 2 °C (Ⅲ) The influence of various factors on the ambient temperature control performance in the URC is as follows: deflector height > VR > deflector angle.
AB - Acceptable temperature is crucial for underground refuge chamber (URC) to ensure the safety and comfort of occupants. A novel temperature control scheme combining mechanical ventilation with deflectors was proposed for URCs. In this study, the effects of ventilation rate (VR), deflector height and deflector angle on ambient temperature control performance and airflow organization of URC were investigated through orthogonal experiments. Results show that: (Ⅰ) The ambient temperature gradient of URC decreases with the increase of VR and deflector height. (Ⅱ) With VR of 350 m3/h, deflector height of 1.40 m, and deflector angle of 0°, compared to the situation without deflectors, the temperature unevenness coefficient can be effectively reduced, the head-to-foot temperature difference can meet the design standard requirements, the waste heat emissions efficiency is increased by 46.1 %, and an average decrease in ambient temperature of 2 °C (Ⅲ) The influence of various factors on the ambient temperature control performance in the URC is as follows: deflector height > VR > deflector angle.
U2 - 10.1016/j.csite.2025.106023
DO - 10.1016/j.csite.2025.106023
M3 - Article
SN - 2214-157X
VL - 69
SP - 1
EP - 15
JO - Case Studies in Thermal Engineering
JF - Case Studies in Thermal Engineering
M1 - 106023
ER -