Abstract
The neutron flux of the n_TOF facility at CERN was measured, after installation of the new spallation target, with four different systems based on three neutron-converting reactions, which represent accepted cross sections standards in different energy regions. A careful comparison and combination of the different measurements allowed us to reach an unprecedented accuracy on the energy dependence of the neutron flux in the very wide range (thermal to 1 GeV) that characterizes the n_TOF neutron beam. This is a pre-requisite for the high accuracy of cross section measurements at n_TOF. An unexpected anomaly in the neutron-induced fission cross section of U-235 is observed in the energy region between 10 and 30keV, hinting at a possible overestimation of this important cross section, well above currently assigned uncertainties.
Original language | English |
---|---|
Article number | 156 |
Number of pages | 11 |
Journal | European Physical Journal A: Hadrons and Nuclei |
Volume | 49 |
Issue number | 12 |
DOIs | |
Publication status | Published - 18 Dec 2013 |
Keywords
- FACILITY
- CERN
- STANDARDS
- SCIENCE
- BEAM