Reliability of sonographic assessment of tendinopathy in tennis elbow

Leon Poltawski, Syed Ali, Vijay Jayaram, Tim Watson

Research output: Contribution to journalArticlepeer-review

40 Citations (Scopus)

Abstract

To assess the reliability and compute the minimum detectable change using sonographic scales to quantify the extent of pathology and hyperaemia in the common extensor tendon in people with tennis elbow.

The lateral elbows of 19 people with tennis elbow were assessed sonographically twice, 1-2 weeks apart. Greyscale and power Doppler images were recorded for subsequent rating of abnormalities. Tendon thickening, hypoechogenicity, fibrillar disruption and calcification were each rated on four-point scales, and scores were summed to provide an overall rating of structural abnormality; hyperaemia was scored on a five point scale. Inter-rater reliability was established using the intraclass correlation coefficient (ICC) to compare scores assigned independently to the same set of images by a radiologist and a physiotherapist with training in musculoskeletal imaging. Test-retest reliability was assessed by comparing scores assigned by the physiotherapist to images recorded at the two sessions. The minimum detectable change (MDC) was calculated from the test-retest reliability data.

ICC values for inter-rater reliability ranged from 0.35 (95% CI: 0.05, 0.60) for fibrillar disruption to 0.77 (0.55, 0.88) for overall greyscale score, and 0.89 (0.79, 0.95) for hyperaemia. Test-retest reliability ranged from 0.70 (0.48, 0.84) for tendon thickening to 0.82 (0.66, 0.90) for overall greyscale score and 0.86 (0.73, 0.93) for calcification. The MDC for the greyscale total score was 2.0/12 and for the hyperaemia score was 1.1/5.

The sonographic scoring system used in this study may be used reliably to quantify tendon abnormalities and change over time. A relatively inexperienced imager can conduct the assessment and use the rating scales reliably.

Original languageEnglish
Pages (from-to)83-89
Number of pages7
JournalSkeletal Radiology
Volume41
Issue number1
DOIs
Publication statusPublished - Jan 2012

Keywords

  • Tennis elbow
  • Ultrasonography
  • Outcome assessment
  • Reliability
  • POWER DOPPLER ULTRASONOGRAPHY
  • LATERAL EPICONDYLITIS
  • ULTRASOUND IMAGES
  • ACHILLES-TENDON
  • REPRODUCIBILITY
  • RHEUMATOLOGIST
  • INJECTIONS
  • EXERCISE

Fingerprint

Dive into the research topics of 'Reliability of sonographic assessment of tendinopathy in tennis elbow'. Together they form a unique fingerprint.

Cite this